Welcome to National Flues Ltd! We use cookies to power essential features and personalise your experience, ensuring a smooth, secure, and ever-improving journey on our website. Your privacy is our priority—cookies help us remember your preferences and enhance your visit without compromising your data. By continuing to browse, you agree to our use of cookies as detailed in our Cookie Policy. Enjoy your visit and thank you for choosing us!
Cookie Preferences
We use different types of cookies for various purposes. Please select which you allow:
The TWPro MB Ventilated Firestop Support Kit is the ideal solution for chimney installation safety, designed by TWPro for UK homes. This premium firestop kit ensures that your chimney meets strict building standards and compliance regulations. Whether you are installing a new chimney or upgrading an... More...
The TWPro MB Ventilated Firestop Support Kit is the ideal solution for chimney installation safety, designed by TWPro for UK homes. This premium firestop kit ensures that your chimney meets strict building standards and compliance regulations. Whether you are installing a new chimney or upgrading an existing one, the TWPro MB kit provides reliable support, safety, and compliance. Perfect for those in search of a high-quality firestop solution, this kit is essential for safe, efficient, and compliant chimney installations across the UK. Less...
Hover to Zoom / Click for Gallery
In Stock
At a Glance
- HETAS Approved & CE Marked
- Meets EN1856-1 safety standards
- Durable stainless steel construction (316L inner, 304 outer with high temperature black coating)
- Includes two ventilated fire stops and a support clamp
- Provides a critical 50mm gap to combustibles
- Supports up to 3 metres of vertical chimney installation
- Suitable for use with wood, oil, gas, and low sulphur coal
Now only
£110.99
Including VAT & Free Delivery
Buy with confidence. If you find this cheaper within 48 hours of checkout, we'll refund the difference.
×
Email Product
Enter your email address to send the product details:
Please Note: All dimensions refer to the internal diameter of flues.
If unsure, please call 01670 206999 to ensure you choose the correct products.
We Won't Be Beaten On Price
At National Flues, we continuously monitor competitor prices. This ensures that we consistently offer you the best deals on all our products. Here’s how we keep your costs low:
Daily Price Matching: Our team adjusts prices to ensure we stay competitive.
Bulk Purchasing Power: We sell a lot, so we can negotiate better rates with suppliers, passing the savings directly to you.
Operational Efficiency: We have streamlined processes to reduce overhead.
Price Match Guarantee: If you find the same product cheaper within 48 hours, we’ll match it and refund the difference.
Free Delivery Over £100: Orders over £100 are free delivery (call us if delivery is required outside the mainland UK).
“I saved 20% on my purchase compared to other retailers. Exceptional service!” – Jane D.
The TWPro MB Ventilated Firestop Support Kit (Ø 150mm) is an essential component for ensuring safe and compliant chimney installations across the UK. This kit includes two ventilated fire stops and a support clamp, making it perfect for T600 all-fuel applications. Designed to allow chimneys to pass between floors—such as from the ground floor through the ceiling to the first floor—it provides the necessary 50mm distance to combustibles.
This maintains safety standards and adheres to fire and building regulations. Each firestop plate is constructed from durable steel and is HETAS approved, CE marked, and compliant with EN1856-1 standards. This kit supports up to 3 meters of vertical chimney installation, making it versatile for various settings.
Invest in this reliable and safety-assured solution for your fireplace needs.
SKU: 37-150-077
Technical Specifications
SKU
37-150-077
Designation
EN1856-1 T600 N1 W V2 L50040 G50; EN1856-1 T200 P1 W V2 L50040 O20
Inner Material
316L Stainless Steel - 0.40mm thick
Outer Material
304 Stainless Steel - 0.40mm thick with High Temperature Black Coating
Vertical Support
Up to 3 metres
Distance To Combustibles
50mm
Fuel Compatibility
Wood, Oil, Gas, Low Sulphur Coal
Approvals
HETAS, CE
Before beginning installation, ensure you have read and understood the manufacturer’s guidelines. The TWPro MB Ventilated Firestop Support Kit is designed for safe chimney installations through floors. Key points to note during installation include:
- Verify that the installation area meets or exceeds the required 50mm gap from any combustible materials.
- Ensure that all components (ventilated fire stops and support clamp) are undamaged and clean before use.
- Follow EN1856-1 standards during assembly; improper installation can compromise safety and performance.
- If installing between floors, confirm the vertical support does not exceed 3 metres without additional compliance measures.
- Always use the designated tools and hardware provided in the kit, and consider professional installation assistance if unsure.
Warnings:
- Do not use the kit if any component is found to be defective or damaged.
- Ensure that the kit is installed in accordance with current UK building regulations and safety standards.
- Consult a professional if installation conditions deviate from standard scenarios.
The kit is used to safely install chimneys through floors, maintaining the appropriate distance from combustibles and ensuring compliance with fire and building regulations.
The kit is suitable for all fuel types, making it highly versatile for various heating appliances.
Yes, the kit is HETAS approved, ensuring it meets high standards for safety and performance.
The TWPro MB Ventilated Firestop Support Kit is designed to maintain a minimum distance of 50mm from combustible materials.
The kit provides support for up to 3 meters of vertical chimney installation.
The designation numbers are EN1856-1 T600 N1 W V2 L50040 G50 and EN1856-1 T200 P1 W V2 L50040 O20.
Yes, it is designed to allow chimneys to safely pass between floors, including from the ground to the first floor.
Delivery Information +
We work relentlessly to ensure you get your order fast.
Estimated delivery for this product is Friday, April 4th.
If you need faster stove or fireplace delivery please give us a call.
We can often reduce longer lead times if we pay the carrier £25 for express delivery.
Visit our Shipping Information page for more information.
Warranty & Returns +
All our products come with warranties. Mi-Flex offers a lifetime guarantee.
Returns for damaged items are covered by insurance; non-damaged returns incur return delivery costs.
Price Match Guarantee +
We will match any price like for like. If you find it cheaper within 48 hours, we'll refund the difference.
Compatible and other products that may be of interest...
Read our buyers guide for this TWPro MB - Ventilated Firestop Support Kit (MB) - Ø 150
TWPro MB Ventilated Firestop Support Kit: Your Comprehensive Guide
When it comes to installing a chimney in your home, safety and compliance with building regulations must be your top priority. The TWPro MB Ventilated Firestop Support Kit is designed to meet these standards and ensure your chimney installation is both secure and efficient. In this guide, we explore the product's features, benefits, installation process, and frequently asked questions to help you make an informed decision.
Understanding the Importance of a Firestop Kit
A firestop kit is a critical safety component, ensuring that when your chimney passes through floors, there is a sufficient gap between the chimney and combustible materials. The TWPro MB kit includes two ventilated fire stops and a support clamp, crafted to provide a 50mm clearance from combustibles. This gap is vital in reducing the risk of fire hazards, thereby protecting your property and loved ones.
Key Product Features
HETAS Approved & CE Marked: This kit is rigorously tested to meet the highest safety standards in the industry, making it a reliable choice for any chimney installation.
Durable Construction: Made from high-grade 316L and 304 stainless steel, the kit is designed to withstand high temperatures and harsh conditions, ensuring longevity and robust performance.
Versatile Application: Whether you use wood, oil, gas, or low sulphur coal, this firestop kit is engineered to be compatible, offering unparalleled performance in diverse heating environments.
Installation Process Demystified
Installing the TWPro MB Ventilated Firestop Support Kit is straightforward but requires careful attention to detail and adherence to best practices. Here’s a step-by-step approach:
1. Preparation: Before beginning the installation, locate a suitable area that maintains a minimum distance of 50mm from any combustible materials. Ensure all necessary tools and safety equipment are ready.
2. Inspection: Examine each component of the kit for any signs of damage. Only use parts that meet the manufacturer's safety standards.
3. Assembly: Follow the detailed guidelines as per EN1856-1 standards. The kit is designed to support up to 3 metres of vertical chimney installation, facilitating a safe passage between floors. Carefully position the ventilated fire stops and secure them with the support clamp provided.
4. Final Check: Once installed, verify the integrity of the installation. Confirm that the clearance is maintained properly and that all components are firmly in place. If there is any doubt, it is advisable to consult a professional.
Addressing Common Concerns
Will this kit work with my specific fuel type?
Yes, the TWPro MB Ventilated Firestop Support Kit is compatible with a range of fuel types including wood, oil, gas, and low sulphur coal. This versatility makes it an excellent choice for different heating systems.
What if my chimney installation exceeds 3 metres?
The kit supports up to 3 metres of vertical installation. For installations exceeding this height, further consultation with a building professional or additional compliance measures might be necessary.
Is professional installation required?
While the installation process is designed to be user-friendly, ensuring the integrity of safety measures is paramount. If you are unsure about any step, it is highly recommended to seek professional installation support to avoid compromising on safety standards.
What regulatory standards does this kit meet?
The TWPro MB kit is HETAS approved and CE marked, adhering strictly to the EN1856-1 standards. This ensures that your installation is fully compliant with UK fire and building regulations.
Advantages of Choosing TWPro MB
Opting for the TWPro MB Ventilated Firestop Support Kit means investing in high-quality materials, superior safety standards, and peace of mind. The product is built to deliver consistent performance under various conditions, ensuring longevity and reliability for your installation. With its meticulous design and robust construction, this kit is a testament to TWPro’s commitment to quality and safety.
Making the Right Decision
Choosing the correct firestop support kit for your chimney installation is a critical decision. With a product that offers advanced safety features, durability, and regulatory compliance all in one package, the TWPro MB Ventilated Firestop Support Kit stands out as an optimal solution. By aligning with the highest industry standards, you are not only ensuring the safety of your home but also enhancing the overall performance of your chimney system.
Conclusion
For those investing in a new or upgraded chimney installation, the TWPro MB Ventilated Firestop Support Kit is an essential component that delivers on both safety and efficiency. Its comprehensive design, backed by industry-standard certifications, guarantees that your installation will be secure, compliant, and long-lasting. With clear instructions and robust construction, this kit addresses all your concerns by combining practicality with advanced safety features. If you have any hesitations or require further assistance, consider consulting with an installation professional who can provide additional insights tailored to your specific requirements.
In summary, the TWPro MB kit is not just an accessory but a crucial element in ensuring that your chimney installation meets all necessary fire and building regulations. It bridges innovation with safety, giving you the confidence to install and use your chimney without worry. The detailed design caters to a variety of scenarios, making it a sensible and reliable investment. Embrace the enhanced safety features and superior performance of the TWPro MB Ventilated Firestop Support Kit today.
Buy now or call 01670 206 999.
National Flues Ltd Verdict
At National Flues, we're proud to offer the TWPro MB Ventilated Firestop Support Kit (Ø 150mm). This high-quality, HETAS approved kit ensures safe and efficient chimney installations. We deliver nationwide and cater to both retail and trade customers, ensuring you get exceptional products and service at unbeatable prices.
This kit ensures safe installation of chimneys through floors, maintaining proper distance from combustibles and adhering to fire and building regulations.
TWPro is known for its high-quality, reliable chimney and fireplace components. Designed to meet stringent safety standards, TWPro products are HETAS approved and CE marked, ensuring performance and compliance.
Ensure your chimney installation is safe, compliant, and built to last—secure the TWPro MB kit now.