National Flues offers the premium Register Plate (K) - 900x600 with no access hole, designed for Ø175 & 200 chimney systems. This high-quality galvanised steel register plate is tailor-made for 180mm and 200mm flue pipes and is ideal for homeowners and professionals seeking reliable chimney accessories that combine safety, durability, and aesthetic versatility.

What it’s for

The Register Plate (K) - 900x600 is used to seal off the base of a chimney, supporting vermiculite and preventing debris from falling into a stove.

Full features & benefits

  • Durable galvanised steel construction offers long-term reliability and weather resistance.
  • Precision dimensions mean a perfect seal against your chimney base, reducing debris and moisture entry.
  • Compatibility with 180mm and 200mm flue pipes provides flexibility for various installations.
  • The included special adaptor simplifies the installation process, saving time and effort.
  • Four fixing angles ensure a robust and secure installation, even in challenging conditions.
  • Customisable finish allows you to blend the register plate with the aesthetic of your home.
  • Supports vermiculite insulation systems by eliminating unwanted access holes while ensuring safe operation.
Now only £49.99
Give us a call if you find it cheaper and we'll normally price match.
  • Fast deliveryMonday, November 17th*
  • Best PriceCall us to beat any price you found online.
  • Secure checkoutCard· Google/Apple Pay· Klarna· Paypal

 

Payment Options

At a Glance

  • 900mm x 600mm precision-cut for an exact fit
  • Constructed from robust 1.5mm galvanised steel
  • Compatible with both 180mm and 200mm flue pipes
  • Special adaptor included for versatile installation
  • Four fixing angles ensure secure mounting
  • Customisable via spray paint to match your stove pipe
  • Designed for use with vermiculite to prevent debris ingress

We Won't Be Beaten On Price

At National Flues, we continuously monitor competitor prices. This ensures that we consistently offer you the best deals on all our products. Here’s how we keep your costs low:

  • Daily Price Matching: Our team adjusts prices to ensure we stay competitive.
  • Bulk Purchasing Power: We sell a lot, so we can negotiate better rates with suppliers, passing the savings directly to you.
  • Operational Efficiency: We have streamlined processes to reduce overhead.

Price Match Guarantee: If you find the same product cheaper within 48 hours, we’ll match it and refund the difference.

Free Delivery Over £100: Orders over £100 are free delivery (call us if delivery is required outside the mainland UK).

“I saved 20% on my purchase compared to other retailers. Exceptional service!” – Jane D.

Have Questions?
Phone: 01670 206999
Email: sales@nationalflues.com

The Register Plate (K) - 900x600 is a crucial component for sealing off the base of your chimney, ensuring no debris from within the chimney stack comes down and interferes with your stove. Constructed from robust 1.5mm thick galvanised steel, this register plate can be tailored on-site to match the base size of your chimney stack. Ideal for use with either 180mm or 200mm diameter flue pipes, it includes a special adaptor, making it versatile and efficient.

You can even spray it to match the colour of your stove pipe for a seamless look. During installation, the included supporting brackets should be cut and secured into the brickwork, providing a sturdy base for the register plate. Any gaps between the brickwork and the plate can be sealed with Fire Cement or High-Temperature Sealant to ensure a secure fit.

For maintenance, it is advised to have chimneys serving solid fuel appliances swept at least once a year to maintain safety and efficiency. However, do not remove the cover plates if vermiculite has been installed as added insulation.

SKU: 94-REG-K

Delivery Information* +

We work relentlessly to ensure you get your order fast. Estimated delivery for this product is Monday, November 17th. This is based on current lead times. Bear in mind that it is a busy time of year. If you need a product delivered by a specific time in the next 7 days, then please give us a call on 01670 206 999. Visit our Shipping Information page for more information.

About National Flues Ltd +

We began over 30 years ago as a fireplace shop in the North East. We now supply hundreds of trade professionals and thousands of retail customers, all across the UK, every month. We are still a family owned business, lead by the MD Neil, and always try our best to deliver the best possible experience. We also price match, so give us a call if you find this cheaper and want to buy from us. Visit our about us page to read a bit more.

Technical Specifications
SKU94-REG-K
Dimensions900mm x 600mm
MaterialGalvanised Steel
Thickness1.5mm
Fixing Angles4
Compatible Flue Diameters180mm / 200mm
Cleaning Holes2
Suitable For InsulationNo
Included AdaptorYes
StockIN STOCK (18)
Our Price£28.36
• Begin by cutting the supporting brackets to match the size of your chimney stack. • Secure the brackets firmly into the brickwork to create a sturdy foundation. • Customise the Register Plate (K) to the exact dimensions of your chimney base. • Place the plate on the fixed brackets and ensure it sits level and flush against the wall. • Seal any gaps between the plate and brickwork using Fire Cement or High-Temperature Sealant to enhance safety. • If required, spray paint the plate to match the colour of your stove pipe for a seamless, coordinated look. • Always follow recommended safety procedures and consider professional assistance if needed.

The Register Plate (K) measures 900mm x 600mm.

The Register Plate and the supporting brackets are made from 1.5mm thick galvanised steel.

Yes, the Register Plate can be sprayed to match the colour of your stove pipe.

This Register Plate is compatible with 180mm and 200mm diameter flue pipes.

This specific model should not be used if you are using vermiculite as added insulation for your flue.

It is recommended to have the chimney swept and maintained at least once a year.

1. Cut the supporting brackets to the size of your chimney stack. 2. Secure them to the brickwork. 3. Cut the Register Plate to size and place it on the brackets. 4. Seal any gaps using Fire Cement or High-Temperature Sealant.

 